Human Calcitonin,CT ELISA Kit
-
中文名称:
人降钙素(CT)酶联免疫试剂盒
-
货号:
CSB-E05131h
-
规格:
96T/48T
-
价格:
¥3900/¥2500
-
其他:
产品详情
-
产品描述:
人降钙素(CT)酶联免疫试剂盒(CSB-E05131h)检测血清、血浆、组织匀浆样本中的CALCA含量。CALCA 是重要靶点。它在机体生理活动里有关键作用。研究机制上,CALCA 参与多种信号通路,其表达异常和疾病发生发展关联紧密。科研聚焦于解析其作用途径,期望通过干预 CALCA 开发治疗疾病的新策略和药物。试剂盒检测范围为4.688 pg/mL-300 pg/mL,该产品适用于基础医学研究中CT蛋白表达水平的定量检测,如钙代谢调控机制探索、骨骼疾病动物模型评估或甲状腺功能相关病理研究,配套的血清/血浆前处理方案及组织匀浆制备指南可满足不同实验体系需求,为科研人员提供稳定可靠的检测工具。本品仅用于科研,不用于临床诊断,产品具体参数及操作步骤详见产品说明书。
-
别名:
CALCA ELISA kit; CALC1Calcitonin [Cleaved into: Calcitonin; Katacalcin ELISA kit; Calcitonin carboxyl-terminal peptide ELISA kit; CCP ELISA kit; PDN-21)] ELISA kit
-
缩写:
-
Uniprot No.:
-
种属:
Homo sapiens (Human)
-
样本类型:
serum, plasma, tissue homogenates
-
检测范围:
4.688 pg/mL-300 pg/mL
-
灵敏度:
1.172 pg/mL
-
反应时间:
1-5h
-
样本体积:
50-100ul
-
检测波长:
450 nm
-
研究领域:
Signal Transduction
-
测定原理:
quantitative
-
测定方法:
Sandwich
-
精密度:
Intra-assay Precision (Precision within an assay): CV%<8% |
|
|
|
Three samples of known concentration were tested twenty times on one plate to assess. |
|
Inter-assay Precision (Precision between assays): CV%<10% |
|
|
|
Three samples of known concentration were tested in twenty assays to assess. |
|
|
|
|
|
|
|
|
|
-
线性度:
To assess the linearity of the assay, samples were spiked with high concentrations of human CT in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
|
Sample |
Serum(n=4) |
|
1:1 |
Average % |
88 |
|
Range % |
81-95 |
|
1:2 |
Average % |
95 |
|
Range % |
92-100 |
|
1:4 |
Average % |
94 |
|
Range % |
90-110 |
|
1:8 |
Average % |
94 |
|
Range % |
89-105 |
|
-
回收率:
The recovery of human CT spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
Sample Type |
Average % Recovery |
Range |
|
Serum (n=5) |
96 |
85-100 |
|
EDTA plasma (n=4) |
92 |
88-99 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-
标准曲线:
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
pg/ml |
OD1 |
OD2 |
Average |
Corrected |
|
300 |
2.379 |
2.252 |
2.316 |
2.173 |
|
150 |
1.794 |
1.760 |
1.777 |
1.634 |
|
75 |
1.305 |
1.284 |
1.295 |
1.152 |
|
37.5 |
0.954 |
0.909 |
0.932 |
0.789 |
|
18.7 |
0.593 |
0.564 |
0.579 |
0.436 |
|
9.4 |
0.372 |
0.349 |
0.361 |
0.218 |
|
4.7 |
0.253 |
0.239 |
0.246 |
0.103 |
|
0 |
0.149 |
0.137 |
0.143 |
|
|
|
-
数据处理:
-
货期:
3-5 working days
Most popular with customers